HYDRAULIC FLASH BUTT WELDER
Hydraulic Flash Butt Welders are designed for Heavy Duty application & High Strength Welding of joints with Large Cross Section.
Construction :
Rigid Fabricated Frame - Minimum Deflection
Encapsulated Welding Transformer - Longer Life
Low impedance Secondary Circuit - Higher Welding Capacity
Features :
Direct acting lever arm clamps with cylinders placed away from flashing zone.
Low friction, accurately aligned movement of Platen.
Hydraulic power pack for positive clamping and upsetting under high pressure.
Controller flashing through flow control.
Accurately machined toolings to match with component profile.
Automatic machine sequence control with PLC for high productivity.
Thyristor power control with tap switches on transformer for optimum weld joint strength
Applications :
Auto Components - Gear Shifter
Chain Link - Ring Gear
Tools - Steering Columns
Wheel Rims - Tractor Links
Machine Data :
Machine Type | UNIT | FBH 100 | FBH 150 | FBH 250 |
---|---|---|---|---|
Rating at 50% duty cycle | KVA | 100 | 150 | 250 |
Clamping force Upsetting force |
kg. kg. |
6000 4000 |
12000 8000 |
18000 12000 |
Maximum Capacity Low Carbon Steel (Expanded Section) Low Carbon Steel (Compact Section) Medium Forging Grade Steel |
Sq.mm Sq.mm Sq.mm |
650 375 320 |
1300 750 650 |
2000 1200 1000 |
Machine Installation Data :
Power Supply | Volts | 415 | 415 | 415 |
---|---|---|---|---|
Freq (Hz) | 50 | 50 | 50 | |
Phase | 1 (2 Lines) | 1 (2 Lines) | 1 (2 Lines) | |
Disconnect Fuse (HRC) Rating | Amps | 250 | 300 | 400 |
Supply Cable Size Cu - 1 Core Al - 3 Core |
mm2 mm2 |
185/Line 300 |
185/Line 300 |
300/Line 400 |
Water Supply (Pressure 3 kg/cm ) Soft Water (Inlet Temp. <300C) |
Lit /min. | 40 | 45 | 50 |
Machine Size :
Dimensions Height Width Length |
mm mm mm |
1500 900 1850 |
1900 1100 2500 |
1900 1100 2500 |
---|---|---|---|---|
Weight (approx.) | kg. | 3500 | 4000 | 4500 |